Standard Library -- Signal
TransferFcn

 
Description:   The TransferFcn block applies a transfer function to a signal. The block assumes a continuous output.  This is attained by having a first order transfer function in the numerator and a second order transfer function in the denominator. The FullTransferFcn block should be used if a second order over second order transfer functions is desired.

The transfer function takes the form:

A[0]s+A[1]
-------------------------------
B[0]s*s+B[1]*s+B[2]

B[0] must never be zero.
 

Inputs:   SimRealVar SigIn[DIMA] – Input Signal (ND)
SimRealVar A[2] – Transfer Function Numerator (ND)
SimRealVar B[3] – Transfer Function Denominator (ND)
 
Outputs:   SimRealVar SigOut[DIMA] – Output Signal (ND)
SimRealVar SigOutI[DIMA] – Integral of Output Signal (ND)
 
States:   InI[DIMA] – Integral of Input Signal (ND)
Out[DIMA] – Output Signal State (ND)
OutI[DIMA] – Integral of Output Signal (ND)
 
Dimensions:   DIMA – Sets the width of input, output and state vectors
 
 

return to component list

Home  |  Products & Services  |  Support Downloads & Demos  |  Documents  |  News & Events  |  About Us  |   Contact

Realtime Technologies, Inc.
© Copyright 2004-2007 Realtime Technologies Inc. All rights reserved.

Realtime Technologies Inc. (RTI) specializes in real time multibody vehicle dynamics, and graphical simulation and modeling.  We offer simulation software applications, consulting, custom engineering, software, and hardware development.  Realtime Technologies’ customer base includes international, government and private entities.  RTI was founded in 1998.